Digital Meter Relay PSM-215B Series
- Small case DIN size [48mm(W)×24mm(H)×72.8mm(D)]
- A terminal for connection power supply is mounted to contribute to reduction of wiring mon-hour
- Whole suface of panel supports IP65
- Corresponding to RoHS Directive
■Input Specification
Code | Measurement range | Resolution | Input resistance | Max. permissible input | Degree of certainty |
---|---|---|---|---|---|
11 | ±99.99mV | 10μV | Approx. 100MΩ | ±50V | ±(0.03%rdb + 2digit) |
12 | ±999.9mV | 100μV | |||
13 | ±9.999V | 1mV | Approx. 1MΩ | ||
1V | 1~5V | 0.4mV | ±50V |
●DC Current Measurement
Code | Measurement range | Resolution | Input resistance | Max. permissible input | Degree of certainty |
---|---|---|---|---|---|
2A | 4~20mA | 16μV | Approx. 50Ω | ±50mA | ±(0.03%rdb + 2digit) |
*For each rannge, the accuracy is applied at (FSC-OFS)/(FIN-OIN)≦1.
*The resolution is a description assuming the initial setting.
■Comparison Part Specification
Number of output points | 3points(select from HH/HI/GO. HI/GO/LO. GO/LO/LL) |
---|---|
Output format | Relay contact output or photo-coupler output |
Relay contact output specification | Contact rating : DC24V 1A (resistance load) |
Mechanical lifetime : 5 million times | |
Electrical lifetime : 100,000 times | |
Photo-coupler output specification | Output rating sink current : 50mA |
Applied voltage : DC30V | |
Output saturation voltage:1.2V or less(at 50mA) | |
setting of judgment value | -9999 to 9999 |
Hysteresis | Settable within 1 to 999 digits for each judgment value |
Action velocity | Relay contact : max.5ms photo-copuler : max.1ms |
Relation condition and behavior | Refer to the table shown below |
Higher and Lower Limits Judgment (HI-GO-LO)
Comparison Condition | Judgment Monitor | Comparison Output | Relay contact | |||
---|---|---|---|---|---|---|
AL1 | AL2 | LO (OUT1) | GO (OUT2) | HI (OUT3) | ||
Display value > Higher limit judgment value | OFF | ON | OFF | OFF | ON | Contact a |
Lower limit judgment value ≦ Display value ≦ Higher limit judgment value | OFF | OFF | OFF | ON | OFF | |
Lower limit judgment value > Display value | ON | OFF | ON | OFF | OFF |
Higher Higher Judgment (HH-HI-GO)
Comparison Condition | Judgment Monitor | Comparison Output | Relay contact | |||
---|---|---|---|---|---|---|
AL1 | AL2 | GO (OUT1) | HI (OUT2) | HH (OUT3) | ||
Display value > Higher higher limit judgment value | OFF | ON | OFF | ON | ON | Contact a |
≦ Display value ≦ Higher limit judgment value | OFF | OFF | OFF | ON | OFF | |
Higher limit judgment value > Display value | ON | OFF | ON | OFF | OFF |
Lower Lower Judgment (GO-LO-LL)
Comparison Condition | Judgment Monitor | Comparison Output | Relay contact | |||
---|---|---|---|---|---|---|
AL1 | AL2 | LL (OUT1) | LO (OUT2) | GO (OUT3) | ||
Display value ≧ Lower limit judgment value | OFF | ON | OFF | OFF | ON | Contact a |
Lower limit judgment value > Display value | OFF | OFF | OFF | ON | OFF | |
Lower lower limit judgment value > Display value | ON | OFF | ON | ON | OFF |
●Relay Contact Output(parallel use with photo coupler output is not available)
Output Rating | DC24V 1A(resistance load) |
---|
●Photo Coupler Output(parallel use with relay contact output is not available)
Output Rating | DC30V 50mA |
---|---|
Output Saturation Voltage | 1.2V or less(at 50mA) |
●External Control
Digital Zero | Fluctuation range from the point is displayed |
---|
■Common specifications
Display | Red 7-segment LED (character height 8mm) |
---|---|
Plarity display | "-" is automatically display when the input signal is negative |
Display range | -9999〜9999 |
Scalling | Offset ± 9999 Full scale ± 9999 |
Overrange warning | OL or -OL is displayed |
Decimal point | Arbitrarily settable |
Zero display | Reading zero suppress |
Range of use temperature and humidity | -10~55℃/35~85%RH( no dew condensation ) |
Range of storage temperature and humidity | -20~70℃/60%RH or less( no dew condensation ) |
Power supply | DC 24V ± 20% |
Power consumption | Approx. 2.2W |
External dimensions | 24mm(H)×48mm(W)×72.8mm(D) |
Mass | Approx. 70g |
Withstand voltage | Between case and power supply terminal / Input terminal / Each output terminal AC 1500V for one minute |
Betoween power supply terminal and input terminal / Each output terminal DC 500V for one minute | |
Between input terminal and each output terminal DC 500V for one minute | |
Insulation resistance | DC 500V, 100MΩ or more in betweenn terminals show above |
Protection structure | IP65(全面) ※JIS C 0920 |
Conforming standards | EN61326-I, EN50581 ( input code 14 is not supported ) |
Measurement sampling speed | Max. 40ms ( 25 times/second) |
Average of movement | Set from none / 2 / 4 / 8 / 16 / 32 |
Display update cycle | Max. approx. 40ms ( 25 times/second ) |
Power supply of sensor | DC 24V ± 5%, 25mA or less |
Regular accessories | Unit sticker, attachment band |
■Optional Specification
●RS-485 communication
Simultaneous Method | Asynchronous method |
---|---|
Communication Methos | 2-wire type semi double ( poling selecting method ) |
Transmission Speed | 38,400bps / 19,200bps / 9,600bps / 4,800bps / 2,400bps |
Start Bit | 1bit |
Data Length | 7bit/8bit |
Parity | Even parity / odd parity / no parity |
Error Detection | BCC check sum |
Stop Bit | 1bit/2bit |
Character Code | ASCⅡ code |
Delimiter | CR/CR + LF |
Transmission Control Procedure | No procedure |
Name of signal for communication | Noniversion (+), Inversion (-) |
Number of connected meters | Max. 31 meters |
Length of line | Max. 500m ( total ) |
●Analog Output
Output Type | Load Resistance | Accuracy | Ripple |
---|---|---|---|
4~20mA | 510Ω or less | ±(0.2% of FS) | 25mVp-p or less |
0~10V | 5KΩ or more | 50mVp-p or less |
Conversion method | PWM conversion method |
---|---|
Resolution | 13bit-worth |
Response time | approx. 100ms |